Re: Duplicate Check not working after Saving CR
Hi Rahul Duplicate check only done before submission of CR and after that It shows only warning as data is already created.
View ArticleSAP MDG uncaught exception " CX_BOL_EXCEPTION"
Hi Experts, After completing configuration for contact person UIBB. Am getting screens as mentioned below, when I fill the data and click on done, it is throwing exception. "CX_BOL_EXCEPTION", Class -...
View ArticleRe: Duplicate Check not working after Saving CR
Hello Rahul,I agree with Sanjay. May be I can explain how this works further. As a part of check cycle, duplicate check would be triggered, provided all the configurations are correct. (Duplicate check...
View ArticleRe: MDGF - Copy account
Hi, Finally we have configured a new menu option with the account specific application MDGF_OG_OVP_FI_ACCOUNT (WD component FPM_ADAPTABLE_OVP -> WD App MDGF_OVP_GEN), instead the generic one, and it...
View ArticleRe: SAP MDG 6.1 SP 3.0 is compatible with SAP ECC EHP6 7.0 ?
Hi Athmaraman, Do we have have any compatibility restrictions between normal ECC system and MDG ECC if the former acts as a downstream system for transactional purposes. We are planning to use MDG 7.0...
View ArticleRe: Duplicate Check not working after Saving CR
Hi Kiran / Sanjay / Avinash, Thanks for all your inputs but we are using BRF+ WF template and thus we are not able to assigned the "Always Executed" options, suggested by Avinash/Kiran, as there are...
View ArticleRe: Duplicate Check not working after Saving CR
Hi, We have configred the WF steps and are able to do the assignments. Now we can see the pop up at approval step as well. Thanks for your input. RegardsRahul Kulkarni
View ArticleRe: How to Data transfer from one table to another table from MDG generated...
First of all, is the target ECC table in the same box as the MDG system or it is a different box (basically, I'm asking whether you have a hub or a co-deployed MDG system). Either way, for flex mode,...
View ArticleRe: How to Data transfer from one table to another table from MDG generated...
Hi Abdullah, Appreciation your guidance ! It will be Co-deployment MDG system so basically both MDG and tables are relaying on same system . Does we can use the MDG generated Table for further...
View ArticleRe: How to Data transfer from one table to another table from MDG generated...
In re-use mode, data only moves to the ECC table after activation. So, during approval, everything is stored in staging tables that you should not have to worry about. So, I would definitely recommend...
View ArticleMDGF 7 : Reports Web Dynpros do not display
Hi Gurus We are implementing MDGF 7 SP06. We activated FIN_MDM_ORG. In Reports menu we have access to some reports for Accounts and Organizational Units but Web Dynpros do not display. We get the 404...
View ArticleRe: MDGF 7 : Reports Web Dynpros do not display
Usually in weblink where you see 404 error , you get service name , pick service name from weblink and activate in SICF.
View ArticleRe: MDGF 7 : Reports Web Dynpros do not display
Hi SICF services names do not display. I suppose there is other content to load. Do those reports use ODP?
View ArticleRe: MDGF 7 : Reports Web Dynpros do not display
Hi Le I am also trying to execute these reports but no luck till date.Currently its going to any standard URL, and we need to change it.If you will get the answer for this please share with me.
View ArticleRe: If Material ledger is Active CR is not going to Activate.
Hi, For MDG-M 7.0 implemented as hub for materials that have mandatory fields like material origin and variance key - how can we create these materials through MDG when we cannot maintain these views?...
View ArticleRe: MDGF 7 : Reports Web Dynpros do not display
Hi Sanjay I had the time to investigate this tonight. Those additional reports are related to Business Function FIN_MDM_ORG You need SAP NetWeaver 7.0 BI Content Add-On 5 SP01 to make something appear....
View ArticleMDG -M Internal number assignment is not possible for the material type FERT
Hi Experts, In MDG-M 7.02 I am getting above error.Is using external number ranges not possible for materials? Thank you
View Article